Oxycon mobile device

Wireless, portable cardiopulmonary stress testing system

Oxycon Mobile from CareFusion lets you determine metabolic response while exercising, working or in settings that traditional, stationary metabolic systems cannot. The device records breath-by-breath data mounted to the subject's body via a comfortable vest and allows testing in children to adults and patients to athletes. 

  • Data is collected through a facemask or mouthpiece and is sent to a host computer system via wireless transmission (telemetry), making the device suitable for use in a non-laboratory environment. View More...
  • Oxycon Mobile's software includes Spirometry, exercise Flow Volume Loops, online registration program for the transmitted data, evaluation software and reporting system.
  • The optional 12-channel ECG is transmitted wirelessly to optimize control.
  • Volume measurements with a very lightweight, precise, bi-directional digital volume transducer (DVT), which can be placed directly at the mouth that is insensitive to water vapour and breathing gases; dead space 30 mL.
  • Sensorbox (SBx): Housing the fast response electrochemical oxygen measuring cell (response 80 ms after digital filtering) and a very fast hot wire carbon dioxide analyser (response less then 80 ms).
  • Data exchange unit (DEx): Unit that collects data from the Sensorbox (ventilation, O2, CO2, SpO2 3 lead ecg and heart rate via polar belt) and sends it telemetrically (range 1,000 m in open space area) to a base station connected to a computer.
  • Software includes automated calculations such as Anaerobic Threshold types (AE, AT, RCP), parameter display shows color-coded upper and lower limits of normal, sub-program macros for user-definable controls such as automated blood pressure recording and more.
  • Optional wireless 12-lead ECG and further external battery pack for long term measurement.

Flow/volume gas measurements
Flow/Volume Type: TripleV, flat fan system
Flow range: 0 to 15 L/s
Resolution: 3 mL
Flow accuracy: 70 mL/s or 3%
Volume: 0 to 10 L
Volume accuracy: 50 mL or 2%
Resistance: <0.1 kPa/L/s at 15 L/s
O2 Analyzer Type: Electro chemical cell
Range: 0 to 25% (optionally 0 to 100%)
t90: 80 ms (after filtering)
Accuracy: 0.05 vol%
CO2 Analyzer Type: Thermal conductivity
Range: 0 to 10%
t90: 80 ms (after filtering)
Accuracy: 0.05 vol%
Ventilation (VE) Range: 0 to 300 L/min
Accuracy: 2% or 0.05 L/min
O2 Uptake (VO2) Range: 0 to 7 L/min
Accuracy: 3% or 0.05 L/min
CO2 release (VCO2) Range: 0 to 7 LPM
Accuracy: 3% or 0.05 L/min
RER Range: 0.6 to 2
Accuracy: 4%
Environmental requirements
Temperature (TEMP) Range: -10 to +50°C
Pressure Range: 375 to 825 mmHg 
(500 to 1100 mbar)
Altitude Range: -1400 to 5500 m
Humidity Range: 15 to 95% (non-condensing)
Battery Type: Lithium-ion
Capacity: 1500 mA
Life: 2 hours
Voltage: 3.6 V
Weight: 45 g
Telemetry Type: Spread spectrum, frequency hopping, duplex
Power: 100 mW
Frequency: 2401 to 2495 MHz
Range: Up to 1000 m (line of sight)
Heart Rate Type: Polar belt
Battery: Built-in lithium cell, 2500 h
Heart Rate Option Type: 1-channel, 3 leads, telemetry
ECG Recording Type: 8-channels, 12 leads, telemetry
ECG leads: Einthoven, Wilson, Nehb, Goldberger
Frequency: 0.05 to 100 Hz
Gain: 5, 10, 20 mm/mV
CMRR: > 120 dB
Sampling rate: 240 Hz or 500 Hz, 12 leads simultaneously
A/D resolution 12 bits
External Battery Type: 3 lithium-ion batteries
Pack Life: Additional 6 hours (total of 8 hours)
Flow/volume gas measurements
Quality system Registration: ISO 13485
FDA: 510(k) market clearance
MDD 93/42/EEC: CE marked
Electrical safety: EN 60601-1
EMC: EN 60601-1-2
X=Standard feature
O=Optional feature
Analyzer unit including O2/CO2 analyzer
X
Battery pack and memory card
X
Telemetry unit
X
Automatic volume calibration unit
X
Manual calibration pump
O
Unit for automatic gas analyzer calibration
X
Calibration gas cylinder and pressure reducer
X
Digital volume sensor (TripleV)
X
Polar belt
X
Pulse oximeter, finger and ear clip
X
Shoulder belt system
X
Accessories, including mask and mouthpieces
X
Ambient module, temperature and pressure
X
Case for comfortable transportation
X
Notebook and printer
O
Replacement battery pack
O
Analog input/output
O
8-channel ECG, 12 leads, telemetric
O
Bicycle ergometer
O
Treadmill ergometer
O
Network
O
Programs
Patient data
X
Automatic volume calibration
X
Automatic gas calibration
X
Ambient conditions
X
Spirometry/flow-volume
X
Breath-by-breath
X
Intrabreath
X
Cardiac output (accord. to Wasserman)
X
Offline blood gases/lactate
X
Resting/exercise ECG evaluation
O
Screen and printer report
X
File output (e.g. Excel)
X
PDF report
O
Layout and exercise profile editor
X
Predicted value editing
X
Treadmill and bicycle ergometer control
X
IntelliSupport interpretation program
X